Posts tagged Access Consulting Sydney
Lift Button Offset Requirements

Based on AS1428.1-2009, lift buttons are required to have a minimum 500mm clearance to a corner wall or other obstruction to ensure that a person with a mobility aid is able to approach the lift buttons without obstructing the lift opening and press the buttons to call the lift.

Read More
Calculating Number of Sanitary and Shower Facilities

If the number of people who will occupy a building is known, it should be used. However, in the absence of more accurate information, Clause D1.13 must be used. D1.13 is used in several Parts of the BCA, such as in calculating minimum exit widths, as well as the number of sanitary and other facilities. D1.13 does not restrict the number of occupants using a building, or enforce any building use or licensing requirements.

Read More
BCA Clause D3.4 Exempted Areas

This provision provides details on buildings or parts of buildings not required to be accessible under the BCA. Clause D3.4 details exemptions to the requirements for access to certain areas within buildings where providing access would be inappropriate because of the nature of the area or the tasks undertaken

Read More
Accessible Adult Change Facilities

An accessible adult change facility is a type of sanitary compartment that includes a hoist and adult size change table in addition to a peninsula-type toilet pan and other fixtures and fittings. Its purpose is to provide a suitable toilet for people with more complex or profound disability who may be unable to use standard accessible toilets.

Read More
BCA/NCC 2022 New Requirements for Livable Housing Design.

We call these new requirements ‘livable housing design’ because they’re based on the Livable Housing Design Guidelines (silver level), first published by Livable Housing Australia. Livable housing design represents a significant step-change to how we’ve traditionally designed housing in Australia.

Read More
Importance of Handrail Heights, Extensions & Terminations

Furthermore it is worth noting that a handrails primary function is to prevent a fall and most serious falls occur when descending - not ascending, therefore it is important to ensure the handrail is at the required height and has the required extensions to provide additional assistance whilst ascending or descending, including terminations which prevent young children from injuring themselves if they are at the same height as the handrail.

Read More
Why Use An ACAA Accredited Access Consultant?

The highest membership class is the an Accredited member. In order to become an Accredited Access Consultant you need to participate in the continuing professional development program, have been an associate member for a number of years, must pass an Accreditation Test and also must have industry referees including two Accredited Access Consultants which provide a reference on the capabilities, knowledge and experience of that person.

Read More
AS1428.1-2009 Standard For Access & Mobility

The current access and mobility standard AS1428.1-2009 is based on research that is more than 38 years old and may be considered significantly out of date. Therefore, it may be reasonable to assume that the access needs of many people with a variety of disabilities in 2021 will not be fully met by complying with this standard.

Read More
New Minimum Accessibility Standards for Housing in the BCA/NCC

It has finally been agreed on the National Building Ministers forum that new minimum accessibility Standards, based on the Silver Performance Level of the Livable Housing Australia (LHA) Design Guidelines, will be incorporated into the new Building Code of Australia (BCA/NCC).

Read More
Accessible Handrail Profile

The handrails must have a diameter between 30mm-50mm with a 50mm clearance to an adjacent wall and must not have any obstructions to the top 270 degree arc. It is highly recommend that builders and designers use 30mm diameter handrails for better grip as the fingers can wrap around the handrail.

Read More
Passenger Lift Compliance and Size

Passenger lifts must comply with Clause E3.6 of the BCA or AS1735.12-1999, which is the Australian Standard referenced in the BCA (Schedule 4 of the BCA). If the lift travels less than 12m the car size must be a minimum 1100mm wide x 1400mm deep and if the lift travels more than 12m, the car size must be a minimum 1400mm wide x 1600mm deep (with the exception of stretcher lifts).

Read More
Performance Solutions

In the simplest terms, Performance Solutions are used to justify not meeting the requirements/measurements outlined in the building code with regards to disability. Performance Solutions allow for flexibility in addressing these Performance Requirements and are utilised when the Deem-to-Satisfy provisions are not met.

Read More
Changing Places Design Specification 2020

Australia has become the first country in the world to regulate for adult change facilities in its building code. From 1 May 2019, the National Construction Code (NCC 2019) requires a new type of public toilet called ‘Accessible Adult Change Facilities’ to be included in certain classes of public buildings.

Read More